How oil extractor sizing works
Quarts, drains, freeboard, and when NO_MATCH is honest.
Vacuum oil extractor sizing
Enter sump quarts, drains before empty, and freeboard. Get the smallest 6.5 or 15 L vacuum class — or NO_MATCH when the job exceeds this ladder.
Required tank L ≈ (quarts × 0.946 × drains) ÷ fill. Fill = 0.85 (15% freeboard) or 0.75 (25%). Classes: 6.5 · 15 L. Above 15 L required → NO_MATCH.
Quarts, drains, freeboard, and when NO_MATCH is honest.
Same tool with room for examples.
When each VEVOR vacuum class fits — and when none do.
No resources match. Try another term.